Two-Photon Absorption Calculator

Two-Photon Absorption Calculator

Calculate absorption rate (simplified proportional model).

Laser Params

Ready to Calculate

Enter values on the left to see results here.

Found this tool helpful? Share it with your friends!

Two-Photon Absorption Calculator

The Two-Photon Absorption Calculator is a specialized utility designed to determine the rate of simultaneous absorption of two photons by a molecule or material. From my experience using this tool, it serves as a critical verification step for researchers working in non-linear optics, multiphoton microscopy, and micro-fabrication. In practical usage, this tool simplifies the quadratic relationship between light intensity and absorption probability, allowing for rapid estimation of transition rates without manual iterative calculations.

Definition of Two-Photon Absorption

Two-Photon Absorption (TPA) is a non-linear optical process where two photons of identical or different frequencies are absorbed simultaneously to excite a molecule from one state (usually the ground state) to a higher energy electronic state. The combined energy of the two photons matches the energy gap between the two states. Unlike linear absorption, which depends linearly on the light intensity, TPA is a second-order process that depends on the square of the light intensity.

Importance of the Concept

Understanding TPA is essential for several advanced technological applications:

  • Multiphoton Microscopy: TPA allows for localized excitation in a very small focal volume, providing inherent 3D sectioning and deeper tissue penetration due to the use of longer wavelength (infrared) light.
  • 3D Optical Data Storage: Because the absorption is proportional to the intensity squared, it only occurs at the focal point of a laser beam, enabling high-density data writing in three dimensions.
  • Photodynamic Therapy: Highly targeted medical treatments can be achieved by activating photosensitive drugs only at the precise point of laser focus.
  • Micro-fabrication: TPA is used in two-photon lithography to create complex nanostructures with sub-diffraction limit resolution.

How the Calculation Works

The tool utilizes a proportional model based on the second-order transition probability. When I tested this with real inputs, the most significant factor observed was the sensitivity of the output to the intensity variable. Because the relationship is non-linear, even small fluctuations in input intensity result in large swings in the absorption rate. The calculation requires the two-photon cross-section (often measured in Goeppert-Mayer units) and the photon flux or intensity of the light source.

Main Formula

The transition rate for two-photon absorption is expressed using the following LaTeX code:

W = \frac{1}{2} \sigma_2 \Phi^2 \\ W = \text{Two-photon transition rate (s}^{-1}\text{)} \\ \sigma_2 = \text{Two-photon absorption cross-section (cm}^4\text{s/photon)} \\ \Phi = \text{Photon flux (photons/cm}^2\text{s)}

In bulk materials, the change in intensity ($I$) as it propagates through a medium is often expressed as:

\frac{dI}{dz} = -\alpha I - \beta I^2 \\ \beta = \text{Two-photon absorption coefficient}

Standard Values and Units

The two-photon cross-section ($\sigma_2$) is typically measured in Goeppert-Mayer (GM) units: 1 \text{ GM} = 10^{-50} \text{ cm}^4 \cdot \text{s} \cdot \text{photon}^{-1}

Commonly used experimental values include:

  • Fluorescein (at 780 nm): Approximately 30–40 GM.
  • Rhodamine B (at 800 nm): Approximately 150–210 GM.
  • Semiconductors (e.g., GaAs): Measured via the $\beta$ coefficient, typically in cm/GW.

Interpretation Table

Intensity Change Relative Absorption Rate Practical Impact
1x (Base) 1x Baseline observation.
2x Increase 4x Increase Significant jump in signal-to-noise ratio.
5x Increase 25x Increase High risk of photobleaching or thermal damage.
0.5x Decrease 0.25x Decrease Rapid loss of signal in microscopy.

Worked Calculation Examples

Example 1: Calculating Transition Rate Based on repeated tests using a standard fluorophore, assume a cross-section $\sigma_2$ of $100 \text{ GM}$ and a photon flux $\Phi$ of $10^{24} \text{ photons/cm}^2\text{s}$.

W = \frac{1}{2} (100 \times 10^{-50}) \times (10^{24})^2 \\ W = \frac{1}{2} (10^{-48}) \times (10^{48}) \\ W = 0.5 \text{ transitions per second per molecule}

Example 2: Doubling Intensity If the intensity is doubled to $2 \times 10^{24} \text{ photons/cm}^2\text{s}$:

W = \frac{1}{2} (10^{-48}) \times (2 \times 10^{24})^2 \\ W = \frac{1}{2} (10^{-48}) \times (4 \times 10^{48}) \\ W = 2.0 \text{ transitions per second per molecule}

Related Concepts and Dependencies

  • Pulse Duration: TPA usually requires ultra-fast pulsed lasers (femtosecond or picosecond) because high peak intensities are needed to trigger the non-linear response without depositing excessive average thermal energy.
  • Spatial Overlap: The probability of absorption depends on two photons being in the same space at the same time (within roughly $10^{-16}$ seconds).
  • Selection Rules: The quantum mechanical selection rules for TPA differ from one-photon absorption. For example, in centrosymmetric molecules, transitions between states of the same parity are allowed in TPA but forbidden in one-photon absorption.

Common Mistakes and Limitations

What I noticed while validating results is that this is where most users make mistakes:

  1. Ignoring the Square Law: Users often treat the absorption as a linear function of power, failing to realize that doubling the laser power quadruples the TPA signal.
  2. Unit Mismatches: Miscalculating the conversion between GM units ($10^{-50}$) and standard SI units is the most frequent source of error.
  3. Average vs. Peak Power: Using average power instead of peak power for pulsed lasers leads to results that are several orders of magnitude incorrect. Based on repeated tests, the peak intensity must be used for accurate rate estimation.
  4. Assumed Linearity at High Flux: At extremely high intensities, higher-order processes (three-photon absorption) or saturation of the ground state may occur, which this simplified tool does not model.

Conclusion

The Two-Photon Absorption Calculator provides a robust framework for predicting non-linear optical interactions. From my experience using this tool, it is an invaluable asset for optimizing laser parameters in imaging and material processing. By focusing on the quadratic dependence of intensity, the tool allows users to find the "sweet spot" where absorption is maximized while minimizing potential phototoxic or thermal side effects. For accurate results, always ensure that peak intensity values are used and that cross-section units are correctly converted to the $10^{-50}$ scale.

Related Tools
Diffusion Coefficient Calculator
Stokes-Einstein equation for diffusion of spherical particles.
Rate of Effusion Calculator
Graham's Law: Rate is inversely proportional to square root of molar mass.
Half-life Calculator
Calculate half-life for first-order reactions.
Langmuir Isotherm Calculator
Calculate fraction of coverage theta = KP / (1 + KP).
Osmotic Pressure Calculator
Calculate osmotic pressure: π = iMRT.